Product Description
The Bit Error Rate Indicator is designed to be used with the  Pseudo-Random Binary Sequence Generator, Model 9422 (not included), to  measure the transmission error rate on a bit stream within a  communication system, in order to assess the reliability of the  communication path.
 
 The module compares two data streams and counts, for a specific period  of time, the number of non-identical bits. Three test durations can be  selected: 1 s, 10 s or 100 s. Error rates can be measured within a range  of 0.01 error per second to 9999 errors per second.
 
 At the end of each test period, the error rate appears in errors per  second on a 4-digit display. The display will blink in case of overflow.  The counting cycle is automatically reset when another test duration is  selected. Each new reading can be announced by a tone, which is useful  for long test periods. This feature can be disabled at any time. The  tone generator cannot be used for a test period of 1 s.
 
 Specifications
 
 Power Requirements: Connection to the Enclosure / Supply Regulator, Model 9420 (not included)
 Clock Input
 Frequency: 5.44 MHz maximum
 Auxiliary Output
 Frequency: 3.57 MHz maximum
 Display: 4 digits
 
 Physical Characteristics
 Dimensions (H x W x D) 83 x 142 x 212 mm (3.3 x 5.6 x 8.3 in)
 Net Weight 0.8 kg (1.8 lb)
     					
     					