SELECT CURRENCY


Alphabetical Manufacturer Category
    Search Site

    Toronto Surplus & Scientific Inc.

    Skip to Main Content »



    Phone: 905.853.0078
    Toll Free: 866.376.0078
    Fax: 905.853.1094

    Category Navigation:

    You're currently on:

    Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested

    Double click on above image to view full picture

    More Views

    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
    • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested

    Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested


    Part Number: SKU13222
    Contact for price
    Add Items to Cart
    Quantity in Stock: 1

    Ask a Question

    Product Description

    Product Details From Manufacturer

    The Single-Phase Under/Over Voltage Relay is a protective relay that is sensitive to both undervoltage and
    overvoltage conditions in single-phase power systems. It trips when the voltage moves outside the set voltage
    limits.

    Voltage setpoint and hysteresis adjustments are provided for undervoltage and overvoltage. Two independent
    sets of contacts are provided: one for undervoltage and one for overvoltage.

    Specifications

    Nominal Input Voltage - 69 Vac
    Maximum Input Voltage - 120% of nominal input voltage
    Undervoltage Setpoint Range - 75% to 100% of nominal input voltage
    Overvoltage Setpoint Range - 100% to 125% of nominal input voltage
    Hysteresis Range - 1% to 15% of nominal input voltage
    Output Contacts - 2 x SPDT: 0.5 A at 120 Vdc; 5 A at 240V ac


    Cosmetic Notes
    Signs of scuffing on outer frame from previous use, traces of dust in crevices. Cosmetic in nature, see pictures.

    Tested and Functional Notes
    This item is TESTED & WORKING, as pictured. See above for any additional notes.
     
     