SELECT CURRENCY


Alphabetical Manufacturer Category
Search Site

Toronto Surplus & Scientific Inc.

Skip to Main Content »



Phone: 905.853.0078
Toll Free: 866.376.0078
Fax: 905.853.1094

Category Navigation:

You're currently on:

Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested

Double click on above image to view full picture

More Views

  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested
  • Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested

Lab-Volt 3816-20 Single Phase Under/Over Voltage Relay w/ Compton Instruments 253-PVBU Tested


Part Number: SKU13222
Contact for price
Add Items to Cart
Quantity in Stock: 1

Ask a Question

Product Description

Product Details From Manufacturer

The Single-Phase Under/Over Voltage Relay is a protective relay that is sensitive to both undervoltage and
overvoltage conditions in single-phase power systems. It trips when the voltage moves outside the set voltage
limits.

Voltage setpoint and hysteresis adjustments are provided for undervoltage and overvoltage. Two independent
sets of contacts are provided: one for undervoltage and one for overvoltage.

Specifications

Nominal Input Voltage - 69 Vac
Maximum Input Voltage - 120% of nominal input voltage
Undervoltage Setpoint Range - 75% to 100% of nominal input voltage
Overvoltage Setpoint Range - 100% to 125% of nominal input voltage
Hysteresis Range - 1% to 15% of nominal input voltage
Output Contacts - 2 x SPDT: 0.5 A at 120 Vdc; 5 A at 240V ac


Cosmetic Notes
Signs of scuffing on outer frame from previous use, traces of dust in crevices. Cosmetic in nature, see pictures.

Tested and Functional Notes
This item is TESTED & WORKING, as pictured. See above for any additional notes.
 
 

Login


New User? Sign Up Here