SELECT CURRENCY


Alphabetical Manufacturer Category
Search Site

Toronto Surplus & Scientific Inc.

Skip to Main Content »



Phone: 905.853.0078
Toll Free: 866.376.0078
Fax: 905.853.1094

Category Navigation:

You're currently on:

Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested

Double click on above image to view full picture

More Views

  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested
  • Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested

Lab-Volt 3815-10 AC/DC Current Sensitive Relay In 4mA - 6A DC/60Hz Out 120Vdc 0.5A 250Vac 8A Tested


Part Number: SKU13225
Contact for price
Add Items to Cart
Quantity in Stock: 1

Ask a Question

Product Description

Product Details From Manufacturer

The AC/DC Current Sensitive Relay is a protective relay that is sensitive to either alternating current (ac) or
direct current (ac). It can be set to respond to either undercurrent or overcurrent conditions. Current setpoint
and hysteresis adjustments, ac/dc and undercurrent/overcurrent selection switches are provided along with a
single set of contacts

Specifications

Current Metering Ranges - 4 to 60 mA; 40 to 600 mA; 0.4 to 6 A
Maximum Input Current - 200 mA for the 4-60 mA range800 mA for the 40-600 mA range8 A for the 0.4-6 A range
Current Setpoint Range - same as selected current metering range
Hysteresis Range- 5% to 50% of selected current metering range
Output Contacts - SPDT: 0.5 A at 120 V dc; 8 A at 250 V ac

Auxiliary Supply - 120Vac 2.5Va

Uses Honeywell Load Guard RP 81

Cosmetic Notes
Minor scuffing on outer frame from previous use and dust in crevices, cosmetic in nature, see pictures.

Testing and Functional Notes
This item is TESTED & WORKING, as pictured. See above for any additional notes.

 
 