SELECT CURRENCY


Alphabetical Manufacturer Category
    Search Site

    Toronto Surplus & Scientific Inc.

    Skip to Main Content »



    Phone: 905.853.0078
    Toll Free: 866.376.0078
    Fax: 905.853.1094

    Category Navigation:

    You're currently on:

    Alpha P45T-3-125-100 Battery Charger Input 600V, 19A. Output 125V, 100A. 3 Phase, 60 Hz. New NOS

    Double click on above image to view full picture

    More Views

    • Alpha P45T-3-125-100 Battery Charger Input 600V, 19A. Output 125V, 100A. 3 Phase, 60 Hz. New NOS
    • Alpha P45T-3-125-100 Battery Charger Input 600V, 19A. Output 125V, 100A. 3 Phase, 60 Hz. New NOS
    • Alpha P45T-3-125-100 Battery Charger Input 600V, 19A. Output 125V, 100A. 3 Phase, 60 Hz. New NOS
    • Alpha P45T-3-125-100 Battery Charger Input 600V, 19A. Output 125V, 100A. 3 Phase, 60 Hz. New NOS

    Alpha P45T-3-125-100 Battery Charger Input 600V, 19A. Output 125V, 100A. 3 Phase, 60 Hz. BRAND NEW / NOS


    Part Number: sku9215
    US$1,985.00
    Add Items to Cart
    Quantity in Stock: 1

    Ask a Question

    Product Description

     Specifications

    Model P45T--3-125-100

    Output V/Ah: 125V, 100A 

    Input V: 480V

    Full Load: 208V=62.4A, 480V=27.0A, 600V=21.6A

    Enclosure: A-600

    Weight KG: 252

    Enclosure: CEMA/NEMA (IP20), 14GA (2mm) steel C/W hinged front access door

    Finish: Phosphatized and primed prior to painting with ASA61, light grey

    Audible Noise: 45 to 65 dBa at 3 ft rating dependant

    Operating Temperature Range: 32 F to 122 F (-0 C to 50 C) Storage -40 F to 185 F (-40 C to 85 C)

    Metering and Control- Standard Features

    - 0.5% Accuracy DC voltage and current metering

    -Remaining and elapsed equalize time

    Control Modes: Manual float/ Equalize toggle

    Control Adjustments(Password protected): Float and equalize voltage, current limit, Equalize period 0-100 hours, float period 0-100 days, equalize mode termination based on voltage, time and/or low DC volts event(s)

    Basic Design Features

    UL/ANSI 1012 Listed, CSA C22.2 107.2 Certified and applicable IEC standard compliant

    ISO 9002-1994 Quality control compliant

    SCR (Thyristor) based rectifier c/w double wound isolation transformer

    Electronic control, current limiting and voltage regulation

    Alarm log, history and events

    Modular construction using the latest powre and microelectronic devices

    Color coded PVC copper stranded wire for control and signals

    30 year design, MTBF of 100 000 hours typical, MTTR less than 1 hour

    Additional Features: 

     Audible Alarm

     
     