    Omron CJ1W-DRM21 Devicenet Master and Slave Unit 24VDC


    Part Number: sku8894
    Contact for price
    Add Items to Cart
    Quantity in Stock: 2

    Ask a Question

    Product Description

    Allows control of up to 32,000 points (2,000 words) per master, and ensures a high degree of simultaneity between data.

    Can be used as both a master and a slave at the same time.

    Equipped with settings and monitor functions aimed at improving both design and startup efficiency. Achieve maximum performance by using in combination with a Configurator.

    Files of master and slave settings can be uploaded and downloaded using memory cards, allowing effective debugging and easier setup.

    Communications protocol    DeviceNet
    Connection methods    Multi-drop and T-branch connections can be combined (for trunk and branch lines) *1
    Baud rate    500 Kbps, 250 Kbps, or 125 Kbps
    Communications media    Special 5-wire cables (2 signal lines, 2 power lines, 1 shield line)
    Special 4-wire flat cables (2 signal lines, 2 power lines)
    Communications distances for
    special 5-wire cables    Baud rate    Network length    Branch line length    Total branch line length
    500 kbps    100 m max.    6 m max.    39 m max.
    250 kbps    250 m max. *2    6 m max.    78 m max.
    125 kbps    500 m max. *2    6 m max.    156 m max.
    Communications distances for
    special 4-wire flat cables    Baud rate    Network length    Branch line length    Total branch line length
    500 kbps    75 m max.    6 m max.    35 m max.
    250 kbps    150 m max.    6 m max.    48 m max.
    125 kbps    265 m max.    6 m max.    135 m max.
    Communications power supply    24 V DC supplied externally
    Max. number of nodes    64 nodes (including Masters, Slaves, and Configurator)

    *1.Terminators are required at both ends of trunk line.

    *2.Indicates the maximum network length when thick cables are used. Reduce the network length to 100 m max. when using thin cables.

    Communications power supply voltage    11 to 25 VDC
    Current consumption    Communications:18 mA max.
    Internal circuit: 290 mA max.

     
     