Product Description
- Frequency 60 Hz
- Current Input Class 0-2A (1A nominal)
- Functions Volts/Amps
- Power Supply 18-60VDC
- Communications RS-485
- System 3 Element Y, 2.5 Element Y, 2 Element Δ, 4 Wire Δ
- Voltage Input 0-416VAC L-N, 0-721VAC L-L
- Max. Burden: 0.36VA per phase at 600V, 0.014VA at 120V
- Current Withstand 100A for 10sec, 300A for 3sec, 500A for 1sec
- Max. Burden: 0.005VA per phase at 11A
- Pass-thru Wire: 0.177 in (4.5mm) max dia.
- Isolation All Inputs and Outputs are galvanically isolated to 2500VAC
- Operating Temperature -30 to +70°C, <95% RH non-condensing
- Sampling 400+ Samples/Cycle, all channels measured simultaneously
- Update Rate 1sec, except 100msec on Watts, VAr, VA
- Communication Protocol: Modbus RTU, ASCII or DNP 3.0
- RS485 Port (rear), IrDA (faceplate)
- Dimensions (H x W x D), Ratings 4.85 x 4.82 x 4.25 in, NEMA12 FACE