    Aerotech TM-5 Transformer Module 200VAC, 5A, 50/60Hz

    Double click on above image to view full picture

    More Views

    • Aerotech TM-5 Transformer Module 200VAC, 5A, 50/60Hz

    Aerotech TM-5 Transformer Module 500VA, 200VAC, 5A, 50/60Hz


    Part Number: sku8877
    Contact for price
    Add Items to Cart
    Quantity in Stock: 2

    Ask a Question

    Product Category: TRANSFORMERS & INVERTERS ...... (< 1 kW / kVA) 

    Product Description

    The TM5 transformer module is used to provide and distribute isolated AC bus supply voltages for up to four Aerotech controllers. It is configured at the factory to provide 28 VAC, 56 VAC, 115 VAC, or a combination of these voltages with a total output power capability of 500 watts. Additionally, the TM5 distributes the applied AC line voltage to each of the auxiliary supply outputs for powering the auxiliary power inputs of other Aerotech products.

    Type     Isolation
    AC Input Configurations     100 VAC, 115 VAC, 200 VAC, 230 VAC
    Peak AC Input Inrush Current     32 Apk     200 Apk
    Operating Frequency     50/60 Hz
    Maximum Continuous Transformer Output Power     300 watts max @ 20°C     500 watts max @ 20°C
    Peak Transformer Output Power     400 watts max @ 20°C     800 watts max @ 20°C
    Short Circuit/Over Current Protection     AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 3 A slow-blow fuse connected to transformer primary winding     AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 8 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding
    Thermal Protection     Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110°C.     Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110°C.
    Secondary Winding Configuration     28 VAC (40 VDC bus); 56 VAC (80 VDC bus); ±10 VDC, ±20 VDC, ±30 VDC, ±40 VDC     28 VAC (40 VDC bus); 56 VAC (80 VDC bus); 112 VAC (160 VDC bus)
    +24 VDC Output     0.9 A max     0.9 A max
     

     
     