Home›Products›Test & Measurement›Specialized & Miscellaneous Test Equipment›ROD-L M30 AC Ground Continuity Test Instrument / Ground Bond 30 Amp
ROD-L M30 AC Ground Continuity Test Instrument / Ground Bond 30 Amp
sku95561 — low stock
$950.00CAD
By ROD-L
<p style="text-align: left;">Electrical</p><ul><li>Output Current: 30A</li><li>Resistance; 0 to 0.15 Ohms, accurate within ± 5% when monitor is at full-scale</li><li>Test Time: 1 to 90 seconds, user-adjustable (5-7 seconds is factory default)</li><li>Line Input Requirements; 115/230 VAC, ± 10%, 44-…
Description
<p style="text-align: left;">Electrical</p><ul><li>Output Current: 30A</li><li>Resistance; 0 to 0.15 Ohms, accurate within ± 5% when monitor is at full-scale</li><li>Test Time: 1 to 90 seconds, user-adjustable (5-7 seconds is factory default)</li><li>Line Input Requirements; 115/230 VAC, ± 10%, 44-66 Hz, up to 360 Watts</li></ul><p style="text-align: center;"> </p><p style="text-align: left;">ROD-L M30 AC Ground Continuity Test Instrument</p><ul><li>Performs ground continuity tests in full compliance with BSI, VDE and IEC</li><li>Test time is adjustable from 1 second to 90 seconds</li><li>Measures AC resistance from Chassis of Device Under Test (DUT) to power-cord ground lead – 0 to 0.15 ohm</li><li>Audible and visual alarms identify faulty ground connections</li><li>Hipot interface enables interconnecting to any ROD-L ROD-L Hipot Test Instrument to form an automatic test system</li></ul><p style="text-align: left;">
ROD-L Hipot Test Systems Interfacing</p><ul><li>The Ground Continuity Test Instrument can be interconnected with any ROD-L Hipot Test Instrument to operate as a fully automatic system</li><li>One connection for DUT, and one start button to press</li></ul><p style="text-align: center;"> </p><p style="text-align: left;">SUPERIOR SAFETY FEATURES</p><p> </p><ul><li>    Front panel receptacle is rated to 8000 VAC</li><li>    Front panel receptacle prevents director operator exposure to high voltage during test</li></ul><p> </p><p style="text-align: left;">Production/Quality Assurance Testing
 </p><ul><li>    After test parameters are preset, a single button actuates the Fully Automatic test cycle</li><li>    Measures ground continuity from chassis ground to the power cord ground pin of the DUT</li></ul><p>    Detects and indicates the following:</p><ul><li>Test in Progress</li><li>Test Failed</li><li>Resistance measurement, 0-0.15 ohm</li><li>Current measurement in amperes</li></ul><p> </p><ul><li>Ground resistance trip point easily preset via rear panel potentiometer</li><li>If the ground resistance exceeds the preset value, a fail is indicated both audibly and visually</li></ul><p> 
 </p>
ROD-L Hipot Test Systems Interfacing</p><ul><li>The Ground Continuity Test Instrument can be interconnected with any ROD-L Hipot Test Instrument to operate as a fully automatic system</li><li>One connection for DUT, and one start button to press</li></ul><p style="text-align: center;"> </p><p style="text-align: left;">SUPERIOR SAFETY FEATURES</p><p> </p><ul><li>    Front panel receptacle is rated to 8000 VAC</li><li>    Front panel receptacle prevents director operator exposure to high voltage during test</li></ul><p> </p><p style="text-align: left;">Production/Quality Assurance Testing
 </p><ul><li>    After test parameters are preset, a single button actuates the Fully Automatic test cycle</li><li>    Measures ground continuity from chassis ground to the power cord ground pin of the DUT</li></ul><p>    Detects and indicates the following:</p><ul><li>Test in Progress</li><li>Test Failed</li><li>Resistance measurement, 0-0.15 ohm</li><li>Current measurement in amperes</li></ul><p> </p><ul><li>Ground resistance trip point easily preset via rear panel potentiometer</li><li>If the ground resistance exceeds the preset value, a fail is indicated both audibly and visually</li></ul><p> 