SELECT CURRENCY


Alphabetical Manufacturer Category
Search Site

Toronto Surplus & Scientific Inc.

Skip to Main Content »



Phone: 905.853.0078
Toll Free: 866.376.0078
Fax: 905.853.1094

Category Navigation:

You're currently on:

Conflow Technologies PD340 / PD-340-C76-1-750 / 487211 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter

Double click on above image to view full picture

More Views

  • Conflow Technologies PD340 / PD-340-C76-1-750 / 487211 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter
  • Conflow Technologies PD 340 / PD340 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter
  • Conflow Technologies PD 340 / PD340 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter
  • Conflow Technologies PD 340 / PD340 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter
  • Conflow Technologies PD340 / PD-340-C76-1-750 / 487211 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter

Conflow Technologies PD340 / PD-340-C76-1-750 / 487211 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter


Part Number: sku7771
US$2,230.00
Add Items to Cart
Quantity in Stock: 1

Ask a Question

Product Description

Conflow Technologies PD 340 / PD340 / PD340C76 Process Data Electro-Magnetic Flow Transmitter / Hygienic Sanitary Meter

PD 340 C 76-1-750
Meterhead No. 487211
Elec modul No. 20004456

See Photos for Configuration
 

Mechanical Specifications:
Meter Size: C76
Nom. Size D in mm: 76
Max flow m3/h: 120
Weight: 5kg

The PD 340 Flow Transmitter is an electromagnetic precision meter for the volumetric measure-ment of liquids that are electrically conductive. The transmitter can be used in applications where a hygienic design is required. The rugged construction of the transmitter makes it suitable for installations where solid particles are present in the liquid.


Advantages:
-Suitable for sanitary applications - Designed especially for the food industry. 
-No moving parts - No maintenance. 
-Robust and compact design - Easy to mount, even in difficult applications. 
-Factory configured to suit customer requirements - Makes installation easy and saves time and money. 
-Constructed to be independent of variations in flow profile - High accuracy, even if the viscosity or the liquid changes. Change between different media, such as milk, cream, and liquids containing solids, without any need for recalibration. 
-Optimised for high accuracy and linearity. Using the linearising function, it is possible to measure within a 1:100 turn down range. Therefore, the meter can normally be chosen to have the same size as the diameter of the pipe work, and the cost of installation and any pressure drop can be minimised. 
-Volumetric measurement in m3, litres, U.S. gallons etc.

Functions:-Pulse and 4-20 mA outputs. 
-Batch control function. 
-Built-in PI flow controller.
-Two built-in counters for totalising the volume flow. 
-Inputs for temperature sensor and digital signal.

 

Specifications:
Flow measurement error: See the graph above 
Current output error: As per the graph, plus ±0.3% of current output range 
Linearity: See the graph 
Repeatability: Max. 0.5 x error, (see the graph) 
Liquid temperature: -30 °C to 100 °C 
Liquid pressure: Max. 10 bar 
Liquid conductivity: Min. 5 μS/cm 
Power supply: 24V AC ±15% or 24V DC ±15% 
Power consumption: Max. 6 W

 

Construction of PD=340:

The PD 340 flow transmitter consists of three parts: meter head, electronic module, and terminal box. The electronic module and the terminal box are the same for all sizes of transmitters.

The Meter head consists of a stainless metering pipe with clamp liners. Two magnet coils are mounted external to the metering pipe. Inside the metering pipe two stainless electrodes are mounted. The measuring section is designed so that changes in flow profile do not affect meter accuracy hence the transmitter has a wide range of flow rates within its linear accuracy. Changes from laminar to turbulent flow do not affect the linear accuracy and changing viscosity has no effect on meter accuracy. The calibration of the meter head is carried out using a computer controlled calibration facility.

* Further specifications available upon request