Clemmer Industries sti-P3 Tank Monitor (Steel Tank Association)
Call for price  Please visit: www.torontosurplus.com for further details.
The STI-P3 is used for maintaining your underground storage system and meeting the CAN4 S-603.1-M85 guidelines for cathodic protection monitoring.
Monitoring of cathodic protection systems has always been a recommendation by the Steel Tank Institute since it is a simple procedure for assuring the continued protection of a long lasting and worthwhile investment.

Comes with Meter, Copper/Copper Sulfate Reference Electrode, Leads, Operation and Maintenance Instructions & Case
Call for price


Hardy Instruments HI-803 / Dynamic Instruments DI-803 Portable Vibration Shaker / Transducer Test Set
$ 4875.00 US  Please visit: www.torontosurplus.com for further details.
This 803 was made by Dynamic. Hardy purchased Dynamic and changed the model from DI- to HI-, but all else remains the same.

Top-of-the-line portable shaker for transducer / accelerometer vibration, verification and calibration.

The HI 803 Shaker has the most operational functionality of any Portable Shaker on the Market. Both vibration frequency and amplitude can be varied over a wide range, and the output from the sensor can be plugged into the Shaker for Sensor Check and Calibration.

In a manual mode, the vibration test level and the test frequency can be set from 10 Hz to 10,000 Hz. In a sensitivity mode, the DI 803 not only vibrates the transducer being tested, but also measures its output and calculates its output sensitivity (mV/unit of motion).

A built-in self-test program checks for accuracy of all calculations.

    SPECIFICATIONS:

    MEASUREMENT UNCERTAINTY
  • Acceleration: 10 Hz to 2 Hz +.3 dB, 2 kHz to 10 Hz +.5 dB
  • Velocity: 20 Hz to500 Hz +.3 dB, 500 Hz to 2 kHz +.5 dB
  • Displacement: 20 Hz to150 Hz +.3 dB, 150 Hz to200 Hz +.5 dB
  • Triax: 30 Hz to200 Hz +.3 dB

    FREQUENCY READOUT ACCURACY
  • 3 Hz to 10 kHz: .001% +1 count

    AMPLITUDE RANGE
  • Maximum Acceleration - - - - -10 g (100 m/sec2), PK
  • Maximum Velocity - - - - - - -10 in/sec (254 mm/sec), PK
  • Maximum Displacement - - - -100 mils (2.54 mm), Pk-PK
  • Generates the peak output accelerations at the frequency ranges and loads as follows:

    This 803 COMES WITH THE FOLLOWING:
  • 0228-0072-01 Special Spanning Wrench
  • 0228-0071-02 Velocity Transducer Mounting Fixture
  • 0228-0071-01 Fixture
  • 0228-0094-01 Screwdriver
  • Power Cord
Operating voltage (120 or 240 Vac) for the built-in charger must be specified.

TTS to TUT Cables and other accessories are available from Hardy.

Additional Specifications available upon request.

Manual available in PDF format on CD, for an additional $10.00 US.
$ 4875.00 US

Mitutoyo Digi-Derm 746, DGE-746, 179-746 Non-Destructive, Electronic Coating Thickness Gage
$ 1695.00 US  Please visit: www.torontosurplus.com for further details.
Applications Nonmagnetic coatings on magnetic substrata
Readings are displayed on the clear LCD screen and can be sent to any Mitutoyo SPC system for data analysis. The Digi-Derm is battery powered for portable use and can also operate on AC power with an optional adaptor.

    FEATURES:
  • Measurements can be taken in both inches and mm
  • Measuring Range: 0-0.059"
  • LCD Resolution: 0.00005"
  • Accuracy:
    +.00008" +1 digit (Range: 0-0.0039")
    +2% +1 digit (Range: 0.004-0.043")
    +3% +1 digit (Range: 0.043-0.06")
    COMES WITH:
  • carry case
  • 905338 cable
  • 937244 cable
  • 965013 cable
  • 513-112 pickup
  • Calibration Standards

$ 1695.00 US

NDT Instruments Ultrasonic Contact NDT Transducers for Flaw Detection, Thickness Gauging and Fluid Level Gauging
Call for price -Please advise which unit Please visit: www.torontosurplus.com for further details.
Contact NDT transducers are compatible with most commercial flaw detectors and thickness gauges.

We have 2 units in stock:
Unit A: Transducer Diameter approx. 9/16" with 5 Pin LEMO Connector
Unit B: Transducer Diameter approx. 3/8" with 5 Pin LEMO Connector
Call for price -Please advise which unit


Panametrics EPOCH 2002 Ultrasonic Flaw Detector Part # 20M02
$ 1800.00 US  Please visit: www.torontosurplus.com for further details.
This is a portable digital ultrasonic flaw detector
The EPOCH 2002 incorporates a 5 inch diagonally measured TV formatted CRT.
The sealed touch-panel keyboard controls all instrument functions and settings, replacing tightly packed switches.
All of the EPOCH's functions and settings are under precise microprocessor control
with absolute calibration in either English or metric engineering units.
The electronically generated graticule assures precise correlation with waveforms, with no possiblity of parallax error.
This unit also has 0.1 dB sensitivity resolution which fulfills the demands of many critical industrial and other test applications.

It is in wonderful condition and comes with:

  • Flaw Detector
  • V103 Transducer, 1 MHZ with 0.50" Nominal Element Size
  • BNC to BNC Lead
  • BNC to Microdot Lead
  • Operation Manual & Padded Carry Case.
    This unit does not have an AC power pack charger, but will work with an external power supply.
    $ 1800.00 US

  • PE Photovac SnapShot Nitrogen Cylinder, 1000 PSI P/N 365029
    Call for price  Please visit: www.torontosurplus.com for further details.
    Nitrogen Contents Under Pressure. PLEASE NOTE: The buyer will be responsible for the safe use of this equipment.
    We do not take any responsibility for how this equipment is used and see it strictly as a novelty/collector item.
    Call for price



    Updated: August 20, 2008
    © 2008 Toronto Surplus & Scientific Inc.