Toronto Surplus & Scientific Inc.

~3
Test - Analyzers - Distortion / Noise- Quick Text Page

Amber 3500 Distortion & Noise Measuring Set
This unit incorporates in a single compact enclosure an ultra low distortion sine-wave generator, a high performance total harmonic distortion measuring system and a wide range, high sensitivity signal level and noise measuring facility. In addition a tunable band pass filter is included allowing the system to function as a selective voltmeter.

Specifications - Generator

  • Frequency Range: 10 Hz to 100 kHz in 4 overlapping ranges.
  • Output Amplitude: +22 dBV to -60 dBV (open circuit) or +18 dBm to -64 dBm into 600 ohm load (oscillator off switch enables it to be used for signal to noise measurements)
  • Amplitude Flatness: 20 Hz to 20 kHz - +/- 0.1 dB., 10 Hz to 100 kHz - +/- 0.5 dB
    Output Level Control: 7 steps of 10 dB and variable control of 12 dB

  • Specifications - Distortion Level and Noise Meter Frequency Range: 10 Hz to 100 kHz in 4 overlapping ranges. Continously variable frequency control simultaneously tunes distorion measuring circuits, frequency selective voltmeter and oscillator.
    This unit has a built-in carry handle and comes with AC Adapter & Manual
    $ 1200.00 US
  • Amber 3501 Distortion and Noise Measuring System
    This unit has an ultra-low distortion sine wave generator, a high performance THD measuring system, and a wide range & high sensitivity signal level and noise measuring facility. In addition, a tuneable band pass filter allows the unit to operate as a selective voltmeter or for manual spectrum analysis. The filter may also be configured as a low pass filter for band limited noise measurements. The instrument also incorporates a comprehensive set of user modifiable filters for noise measurements to various standards.

      SPECIFICATIONS:
      GENERATOR:
    • Frequency Range: 10 Hz to 100 kHz
    • Output Power: -60 dBm to +20 dBm into 600 ohm load
    • Output Amplitude Flatness: 20 Hz to 20 kHz +/-0.1 dB
    • Output: Either Balanced (ring-tip-sleeve connector) or Unbalanced (BNC connector)
    • Signal Distortion: 10 Hz to 20 kHz <0.001%

      DISTORTION, LEVEL & NOISE METER:
    • Frequency Range: 10 Hz to 100 kHz
    • Input Amplitude Range Distortion: +40 dBm to -30 dBm, wide band level to -70 dBm, narrow band level to -120 dBm
    • Input Impedance: 100k Ohms shunted by <100 pF
    • Input Residual Noise: <-110 dBV or 3 uV
    • True RMS readings for waveforms with a crest factor <3
    • Fundamental Rejection: 10 Hz to 20 kHz >100 dB
    • Filters: filter 1 = 400 Hz high pass, filter 2 = 30 kHz low pass, filter 3 = 80 kHz low pass, filter 4 = optional "A" weighting, CCIR
    • Input monitor connector for external oscilloscope monitoring of the fundamental
    • Distortion monitor for external monitoring of the waveform with the fundamental removed

    $ 1500.00 US

    Amber 5500 Programmable Distortion & Noise Measurement System
    The 5500 has the Improved Performance & High Speed options as well as firmware version 4.10 which is the most recent version.

      SPECIFICATIONS:
      Signal Source
    • Frequency Range 10 Hz to 100 kHz resolution to 0.005%
    • Amplitude Range 10 Vrms to < 1 mVrms open circuit
    • THD 50 Hz to 10 kHz <0.005% (-106dB)
    • Unbalanced, Floating, or Grounded Output (Balanced 600 ohms, Balanced 900 ohms, Unbalanced 50 ohms)

    • Analyzer Section
    • Frequency Range 8.5 Hz to >500 kHz
    • Level Range 100 Vrms to <10 uVrms (+40 dBV to -100 dBV)
    • Level Flatness +- 0.25 dB or better
    • Wideband Residual Noise (600 ohms, 20 Hz to 100 kHz, A weighting) <2.5 uV / -112 dBm
    • Narrowband Residual Noise (600 ohm, 1 kHz bandpass) <0.7 uV / -123 dBm

    • Frequency Measurement
    • 9.5 Hz to 105 kHz, 5 digits
    • accuracy better than 100 ppm

    • THD + N Measurement
    • frequency range 9.5 Hz to 105 kHz
    • THD+N range >32% to 0.0000% (>-10 dB to -120 dB)
    • Fundamental rejection 120 dB or better

    • Standard Filters
    • 400 Hz High Pass, 60 dB per decade, Butterworth Response
    • 30 kHz Low Pass, 60 dB per decade, Butterworth Response
    • 80 kHz Low Pass, 60 dB per decade, Butterworth Response

    • IEEE-488 Interface


    Special 900 ohm unit, ideal for telephone testing.
    $ 2650.00 US

    HP 331A / Agilent 331A Distortion Analyzer
    This unit measures total disortion levels of 0.1%-100% full scale in 7 ranges at any frequency between 5 Hz to 600 kHz; harmonics are indicated up to 3 MHz.
    $ 150.00 US

    HP 3335A / Agilent 3335A Synthesizer / Level Generator, 200 Hz - 81 MHz
    This unit combines the frequency, accuracy and stability of a synthesized generator with time-saving convenience of digital sweeper. It incorporates a state-of-the-art attenuator with accuracies of up to + .025 dB over the 81 MHz frequency range. Frequency stability up to + 1 x 10-8 / day is provided by an internal temperature-controlled oscillator.
    SPECIFICATIONS
    Resolution: .001, Harmonic Distortion: 200 Hz-10 MHz <-45 dBc; 10 MHz-80 MHz <-40 dBc, Amplitude Range -88.74 dBm to + 13.01 dBm depending on options and impedance, HP-IB.
    $ 3,800.00 US

    HP 333A / Agilent 333A Distortion Analyzer
    This unit is the same as the 331A, but also features auto-nulling which measures down to 0.1% full scale distortion and a
    high pass filter which attenuates frequencies below 400 Hz to minimize hum.
    $ 215.00 US

    HP 334A / Agilent 334A Distortion Analyzer
    This auto-nulling distortion analyzer measures down to 0.1% full scale distortion. It comes with all the bells and whistles: a Frequency Range of 5 Hz to 600 kHz, Voltmeter Range of 300 microV-300V and also has Fundamental Rejection >80dB, 1 kHz High Pass Filter and RF D+etector input which has a range from 550 kHz to 65 MHz with a 1 kHz high pass filter. Good analyzer, good price.

      No Options: $250.00 US
      OPT 001: VU Characteristics (Measures V.U. Volume Units) $ 250.00 US

    HP 339A / Agilent 339A Distortion Measurement Set
    The 339A measures total Harmonic Distortion, True RMS Volts and has a built-in sinewave oscillator which is phase-locked to the meter input receiver. This unit measures THD as low as 0.0018% over a 10 Hz to 110 kHz, including harmonics to 330 kHz. Distortion measurement range is 0.01% to 100%. The oscillator frequency range is 10 Hz to 100 kHz. The output level is variable from 1mV to 3 V RMS into 600 ohms. Voltmeter range is 1mV to 300 V RMS full scale.
    $ 950.00 USED, $ 1895.00 Like New

    Return to the Toronto Surplus & Scientific, Inc. Homepage


    Updated: June 11, 2008