| | AccuFiber / Luxtron 100C Optical Fiber Temperature Control System
$ 1200.00 US Please visit: www.torontosurplus.com for further details.
Used in the following applications: Semiconductor Wafer Processing, Glass Optical Fiber Drawing, Heat Treatment in Induction Furnaces, Sintering, Combustion Research.
Features:
High resolution of 0.01°C
Wide range of 100° to 4000°C
Exceptional stability of 0.1°C per year
Fast response of 10kHz
EMI immunity
Number of Channels: 1 to 8 Optical or Thermocouple
$ 1200.00 US
|
| | Hamamatsu H6240-02 Photon Counting Head
$ 750.00 US Please visit: www.torontosurplus.com for further details.
H6240 Series are photon counting heads incorporating a PMT,
high speed amplifier/discriminator/high voltage power supply
circuits in a housing.
FEATURES:
- Compact / TTL Output, Integrated Photon Counting Circuit, with Low Noise Photomultiplier Tube and Power Supply
- No adjustments required
- High voltage power supply incorporated
- Requires only +6 Vdc source
- Compact and lightweight
- Spectral Response: 185nm to 900 nm
APPLICATIONS:
- Chemiluminescence detection
- Bioluminescence & fluorescence detection
- Other low level light detection
$ 750.00 US
|
| | Hamamatsu H7421-40 Photon Counting Head with M9011 Power Supply & Olympus Lens
$ 2900.00 US Please visit: www.torontosurplus.com for further details.
The H7421-40 contains a photomultiplier tube having a GaAsP photocathode. The unit also has a thermoelectric cooler, which reduces thermal noise generation by keeping the photocathode at a constant temperature.
SPECIFICATIONS:
- Spectral Response Range: 300nm - 720nm
- Peak Wavelength: 550 nm
- Cathode Type: GaAsP
(Comes with a M9011 power supply and Olympus U-TV1X-2 / U-CMAD3 lens)
$ 2900.00 US
|
| | Harmonic Generator / Wavelength Convertor
Call for price Please visit: www.torontosurplus.com for further details.
Harmonic generators are used to convert wavelengths. This unit has a few crystals inside, but we do not have any information or specifications for this unit.
The unit measures approx. 8" x 6" x 6" (not including the base)
Please CLICK HERE to see an array of photos. Call for price
|
| | Newport 818-IR Germanium Detector (800–1800 nm) with Matched OD3 / 883-IR Attenuator
$ 395.00 US Please visit: www.torontosurplus.com for further details.
The 818 Series Cylindrical Detectors (818-UV, 818-SL, 818-IR, 818-IG) are offered for broad wavelength ranges covering UV, visible, near-IR, and IR regions. They use the finest large-area planar-diffused PIN silicon, indium gallium arsenide, germanium PIN or inverted-channel silicon detectors. Each is optimized for zero-bias operation to provide the low noise, high stability and uniformity demanded by critical radiometric measurements. Compact packaging, universal mounting holes and BNC-terminated cabling make incorporation into experimental, production and field applications straightforward.
Comes with the Manual Spectral Range: 0.78-1.8 µm , complete specifications available upon request. 1 in stock $ 395.00 US
|
| | Newport 818-SL Calibration Module 818 Series Detectors
Call for price Please visit: www.torontosurplus.com for further details.
2 in stock Call for price
|
| (Photo shy) |
Newport 818-SL Germanium Detector (800–1800 nm) with Matched OD3 / 883-IR Attenuator
Please visit: www.torontosurplus.com for further details.
|
| | Newport 818J-08B Pyroelectric Energy Detector with Mounting Post
$ 795.00 US Please visit: www.torontosurplus.com for further details.
Precise measurements of pulsed laser energy can be accomplished with Newport’s 818J Series Energy Detectors, which utilize crystalline pyroelectrics. This detector is packaged in an EMI-shielded cylindrical housing that mounts directly to our English posts. Calibrated measurements can be performed by ordering the /CM versions of these detectors for use with Newport’s 1835-C and 2835-C Optical Meters.
The 818J-08B detector features a compact, low-profile design, thus allowing energy measurements in very tight spaces. This detector can be used on its back or mounted on a post, for either vertical laser setups or horizontal laser beams.
SPECIFICATIONS:
-
Spectral Range : 0.19 µm - 20.0 µm
- Maximum Energy: 25 mJ (at 15 sec pulse width)
- Maximum Pulse Width: 50 µs
Complete specifications available upon request. $ 795.00 US
|
| | Newport 818J-50B / 818J-50B/CM Pyroelectric Energy Detector with Calibration Module
$ 950.00 US Please visit: www.torontosurplus.com for further details.
Precise measurements of pulsed laser energy can be accomplished with Newport’s 818J Series Energy Detectors, which utilize crystalline pyroelectrics. This detector is packaged in an EMI-shielded cylindrical housing that mounts directly to our English posts.
Calibrated measurements can be performed by ordering the /CM versions of these detectors for use with Newport’s 1835-C and 2835-C Optical Meters.
Large expanded beams can be accommodated with detector diameters of 25 and 50 mm. Black-organic coated 818J-25B and 818J-50B detectors are suitable for most applications. This coating flattens spectral response from UV to deep IR and eliminates beam retro-reflection, while providing more damage resistant operation, but repetition rates are limited to 50 and 100 pps respectively.
SPECIFICATIONS:
-
Spectral Range : 0.19 µm - 20.0 µm
- Maximum Energy: 1.01 J (at 15 sec pulse width)
- Maximum Pulse Width: 400 µs
Complete specifications available upon request. $ 950.00 US
|
| | Newport 883-SL OD3 Attenuator for 818 Series Detectors
Call for price Please visit: www.torontosurplus.com for further details.
Pictured is the 883-IG, but the 883-SL looks the same. 3 in stock. Call for price
|
| | Newport 883-UV OD3 Attenuator for 818 Series Detectors
$ 49.00 US Please visit: www.torontosurplus.com for further details.
Pictured is the 883-IG, but the 883-UV looks the same. $ 49.00 US
|
| | Oriel 7072 Detection System Unit
$ 875.00 US Please visit: www.torontosurplus.com for further details.
$ 875.00 US
|